The Cool Shield CRAC Extension is designed to be a highly effective, customizable and cost-effective solution for extending your cooling unit return up to the return plenum. Creating this direct connection allows the cooling unit to receive warmer air which provides significant benefits for your data center cooling.
The Ceiling Grid Vent System is designed to aggressively vent air from equipment rooms, closets or Data Centers . The unit easily installs in a standard 2’x2′ ceiling grid and uses nine, professional grade 120mm DC fans to aggressively, but quietly, vent up to an impressive 575 CFM of air. The fans are automated by using two independent temperature controllers with the first turning on one bank of fans at 80°F and the second controller turning the remaining fans on at 88°F.
Many data centers have invested in aisle containment solutions to increase their cooling efficiency. However, gaps in and around the server cabinets can seriously diminish the effectiveness of the containment. It is critical to properly seal any air pass through from the hot aisle to the cold aisle.
The Ceiling Grid Vent System is designed to aggressively vent air from equipment rooms, closets or Data Centers. The unit easily installs in a standard 2’x2′ ceiling grid and uses nine, professional grade 120mm DC fans to aggressively, but quietly, vent up to an impressive 575 CFM of air. The fans are automated by using two independent temperature controllers with the first turning on one bank of fans at 80°F and the second controller turning the remaining fans on at 88°F.

Effective and efficient vertical strips overlap, to separate data center aisle supply and exhaust air.

Effective and efficient vertical strips overlap, to separate data center aisle supply and exhaust air.

Effective and efficient vertical strip walls overlap and separate data center aisle supply and exhaust air.

Framed panels keep aisles contained when missing cabinets/rows. Made to size of cabinets, swap out as you add to rows.

Solid fixed vertical partitions to seal airflow in the hot aisle or cold aisle of a data center.

Overlapping solid panels with thermal release for top panel to slide down to allow for fire suppression

Clear wall panels, full or partial walls, to isolate the cold or hot aisle by filling gaps between or above

Designed To Be Installed Under Water Based Fire Suppression

Hinged door solution provides high performance and aesthetics to your aisle entry ways

Self-closing hinged door system provides attractive and functional containment to aisle entry ways.