Today’s data centers require continuous uptime. That target is why ABB’s Conceptpower DPA 120 is based on Decentralized Parallel Architecture (DPA). Only a truly redundant architecture like DPA allows online modules to be swapped out while the system is running. Each high-reliability, standardized module is self-contained and can be swapped at any time, so nothing has to be ever switched off – making routine maintenance safe and easy.
Conceptpower DPA 120 is designed to secure continuity of critical operations for small to mid-sized data centers, server rooms and other IT applications. It also protects industrial automation processes, healthcare facilities and many other vertical markets where operations are of a critical nature.





Features
BASIC SYSTEM CONFIGURATION THE MODULE INCLUDES:
- 20kW
- True Online Double Conversion UPS
- Built-In Modular Isolation
- Built-In Backfeed Protection
- Individual Module Display
- HMI Interface With Mimic Diagram And LCD Providing Information In Five Languages
THE FRAME INCLUDES:
- 120kW Rated Power In Single Frame
- Bottom Cable Entry (Standard)
- Rectifier, Bypass Terminals (Single Or Dual-Input Mains Connection Available) And UPS Output Terminals
- Battery Breakers And Output Switches For Each Module Set
- Graphical Color Touch Screen System Display
- Communication Interfaces: RS-232 And USB Ports, I/O Dry Contacts (E.G. EPO, GEN On) And External Bypass Interlock
OPTIONS
- Battery Monitoring
- Seismic Bracing
- Maintenance Bypass Cabinet
- Control And Monitoring (Modbus RS-485, Modbus TCP/IP, SNMP, Bacnet And Others)
- Line-And-Match Battery Cabinets
Specifications
GENERAL DATA CONCEPTPOWER DPA 120 UL UPS
- System Power Range 20kW–600kW
- Nominal Power/Module 20kW
- Nominal Power/Frame (Capacity) 600kW
- Output Power Factor 1.0
- Topology Double Conversion, Transformerless, Modular, Decentralized Parallel Architecture
- Parallel Configuration Up To 6 Modules In One Frame / Up To 5 Frames In Parallel
- Cable Entry Bottom
- Serviceability Front Access Only
- Back-Feed Protection Built-In (Standard)
- Connection 5-Wires, 3-Phase + Neutral + Ground
INPUT
- Nominal Input Voltage 3 X 208/120V + Neutral + Ground
- Voltage Tolerance < 100% (–15%, +10%), < 80% (–20%, +10%), < 60% (–30%, +10%)
- Input Distortion THDi < 4% At 100% Load
- Frequency Range 50/60Hz ± 5%
- Power Factor 0.99 @ 100% Load
- Walk In/Soft Start Yes
OUTPUT
- Rated Output Voltage 3 X 208/120V + Neutral + Ground
- Voltage Tolerance ± 2.5%
- Voltage Distortion THDv < 2% In Linear Mode
- Frequency 50/60Hz
EFFICIENCY
- AC-AC Up To 94% At Nominal Load
ENVIRONMENT
- Protection Rating IP 20
- Storage Temperature −25° To +70°C
- Operating Temperature 0° To +40°C
- Altitude (Above Sea Level) 1000 M Without De-Rating
BATTERIES
- Number Of 12V Jars/String 25 – 35 Jars
- Types VRLA, NiCd
- Battery Charger Decentralized Charger In Each Module Set
COMMUNICATIONS
- User Interface Graphical Touch Screen (One Per Frame As Standard) Decentralized LCD + Mimic Diagram (One Per Module As Standard)
- Communication Ports USB, RS-232, Voltage-Free Contacts, SNMP (Optional)
- Customer Interface Remote Shutdown, Gen-Set Interface, External Bypass Contact
COMPLIANCY
- Safety UL 1778 5th Edition, CSA C22.2 No. 107.3-14 Third Edition
- EMC IEC/EN 62040-2 C3
- Manufacturing ISO 9001:2008
WEIGHT, DIMENSIONS
- Weight (System With 6 Modules) 1517 Lbs. (688 Kg)
- Dimensions WxHxD 31.16″ X 77.76″ X 35.17″ (791 X 893 X 1975.5 Mm)